2.5kva 24v mppt pcu (cu) – Devsol Energy

2.5kva 24v mppt pcu (cu)

26,800.00

NEXUS SOLAR is a globally recognized leading Solar off-grid MPPT PCU provider making India Self- reliant on solar energy. We use advanced MPPT technology in our Solar off-Grid PCU that can simultaneously run the load and charge the battery.

Description

NEXUS SOLAR ENERGY is a globally recognized leading Solar off-grid MPPT PCU provider making India Self- reliant on solar energy. We use advanced MPPT technology in our Solar off-Grid PCU that can simultaneously run the load and charge the battery. suitable lead- Acid batteries, as well as flooded, sealed and gel type, these controllers check the output of PV module, Supply Power to a DC load and fixes the power issues that PV module Can produce to charge the battery. Our Solar off-Grid MPPT PCU stand apart from the rest because of their high- quality design and multiple features we have packed into it to make your life easier.

Features

  • Big Data Display
  • Built-in Energy Meter Maximized Solar Usage through Intelligent modes.
  • Remote monitoring and Data logging with lot 40% less panel required than other PCUs RS-232(industrial Standard MODBUS) Incorporated with Microchip.
  • DSP Engines IGBT Based design.
  • fast charging wide range MPPT input configurable user Setting 6 stages battery charging Multiple Battery Selection Sleek.
  • Aesthetic design Works as standalone solar inverter in case of No- grid Safety and protections.

NEXUS 2.5KVA 24V MPPT PLUS PCU

Model MPT2.524VPLUS
Used For Residential
Type Solar Inverter
External Battery Support Yes
Rechargeable Battery NO
Power Output 2300 W
Battery Capacity 200 mAh
Warranty Duration 24 Months
Light Source Solar/Grid
Operating DC voltage 24
SPV Open Circuit Voltage Range(min – max) 36 – 90
Max SPV Power 2
Switching Element IGBT Module
Controller DSP
Efficiency 97%
Battery Charging Stages 5( Software, Boost, Absorption, Float, Equalize)
low cut off 10.5/Batt+/-2%
low cut off recovery 11.5/Batt+/-2%
low Buzzer 10.7/Batt+/-2%
High Cut off 15.5/Batt+/-2%
High cut off recovery 15.0/ Batt+/-2%
Boost Charging Volt by SPV(TUB) 14.5/Batt+/-2%
Boost Charging Volt By Grid(TUB) 14.0/Batt+/-2%
Charging Current By Grid 10a+/-2%
No load Battery Current 0.02
Output No load 230+/-2%
Overload 1900 W
Output low retry 1 Time
Output Short Circuit 1 Time
Display 16 x 2 LCD
Parameters Solar Voltage Current
Status Inverter Status, Main Status, Charge Status
No. of phase 1 phase – 3 Wire P,N,E
Voltage Range(inverter) 100-280+/-2%
Frequency Range 45-55+/-2%
Output Voltage 230+/-2%
Changeover(Mains to Inverter) <10ms
Output power Factor 0.8
Overload Retry 3 Times
Switches System ON/OFF, Mode Selection Hybrid/ Smart, INV / UPS Selection
Indication(LED) Inverter on, Mains In range, Battery low/ High Charger on, Overload, Faults
Alarm(Audible) Battery Low, Overload, Charger on, Inverter On, Solar Charger on
Protection Overload, Short Circuit Protection, Over Voltage, SPV Surge and Transient Protection(MOV Varistors), Reverse Polarity of Battery, Over temperature Protection, Under Voltage and Over Voltage Protection
Cooling Forced Air Cooling(Temp Controlled)
Operating Temp 0-50
Operating Humidity 95
Protection Class IP20
Dimension(LxWxH) 750x500x350
Weight 41 Kg
Voltage Range(UPS) 175-255+/-2%
Solar Support 2340W

Additional information

Weight 25 kg
Dimensions 75 × 50 × 35 cm